System Enclosure |
| Operating Temperature Range: |
-25° to +50°C (non-condensing)
|
| Storage Temperature Range: |
-40° to +70°C |
| Physical Size: |
24.0” x 20.0” x 6.0”
|
| Rating: |
NEMA 4X
|
| Material: |
Stainless Steel |
| |
Standard Measurements |
| Plane of Array (POA) Solar Irradiance:
(silicon pyranometer) |
Typical Error |
± 5% |
|
Stability |
< ± 2% change over 1 year period
|
| Back of Module (BOM) Temperature:
(silicon thermistor) |
Accuracy |
< 1°C |
| AC Power/Energy (including current transformers):
|
Accuracy |
< ± 2% |
| |
System Options |
Basic Weather Station
|
|
|
| Ambient Temperature: |
Accuracy |
< 1°C
|
| Wind Speed:
(cup anemometer) |
Starting Threshold |
1.75mph
|
|
Accuracy |
< 0.1 m/s (5 m/s to 25 m/s) |
| Wind Direction: |
Range |
360°
|
|
Linearity
|
< 1% |
|
Dead Band |
8° maximum, 4° typical |
Advanced Weather Station |
|
|
| Ambient Temperature: |
Accuracy |
< 1°C
|
| Wind Speed:
(sonic anemometer) |
Range |
0 to 60 m/s |
|
Accuracy
(0 to 35 m/s) |
Greater of ± 0.3 m/s or ± 3%
|
|
Accuracy
(35 to 60 m/s) |
± 3%
|
| Wind Direction:
(sonic) |
Azimuth
|
0 to 360° |
|
Accuracy |
± 3% |
| Precipitation:
|
Accuracy |
± 5° (wind induced error excluded)
|
| Barometric Pressure: |
Range
|
600 to 1100 hPa |
|
Accuracy |
± 1 hPa |
| Relative Humidity: |
Accuracy |
± 3%RH (0 to 90%RH) |
|
Accuracy
|
± 5%RH (90 to 100%RH)
|
Battery Storage Monitoring |
|
|
| Voltage (8 to 100V): |
Accuracy |
± 0.1V
|
| Current (including shunt) |
Accuracy |
± 1.5% |
Net Energy |
|
|
| AC Power/Energy (including current transformers): |
Accuracy |
< ± 2% |